RMIT University researchers have developed a prototype X-ray detector that could support more accurate and reliable medical imaging by reducing electrical noise and improving the consistency of measurements.
The postage-stamp-sized devices, measuring approximately 2 cm by 2 cm, use perovskite, a class of semiconductor materials known for their sensitivity to X-rays. However, achieving predictable measurements from perovskite-based detectors has remained a challenge.
According to RMIT, the research team addressed this by replacing the conventional top electrode of the detector with graphene, a one-atom-thick layer of carbon, while leaving the rest of the device unchanged.
The resulting prototype demonstrated a linear response to X-ray exposure, meaning its electrical signal doubled when the X-ray dose doubled. Laboratory testing also showed that the graphene-enabled design reduced background electrical noise by a factor of one million compared with a conventional device.
Lead researcher Dr Babar Shabbir from RMIT’s School of Science said the development addressed a significant barrier to using perovskite detectors in practical applications.
“Perovskites are exceptionally good at detecting X-rays, but getting a predictable response from them has been a longstanding challenge,” Shabbir said.
“With most devices, doubling the X-ray dose doesn’t necessarily double the signal, which makes calibration difficult.”
He said replacing the top electrode with graphene produced a more predictable signal while significantly reducing background noise.
“These are still early results, but they show a promising new direction for developing more accurate and reliable X-ray technologies,” Shabbir said.
Co-author Professor Jacek Jasieniak from Monash University said the findings demonstrated an approach to improving detector performance without changing the material responsible for absorbing X-rays.
The technology could have potential applications in healthcare imaging, security screening, industrial inspection and radiation monitoring, although it has not yet been tested in clinical imaging systems.
Co-researcher Dr Muhammad Nadeem from the University of Wollongong said further work would be needed to establish how the findings could translate into practical imaging technologies.
“This is not a hospital-ready device,” Nadeem said.
“But we’ve shown that it’s possible to dramatically reduce noise while maintaining a reliable signal, and that’s an important result.”
Future research will focus on scaling up the technology, integrating it into imaging systems and evaluating its performance in real-world environments.
The findings, titled Dirac-source linear X-ray detection diode, have been published in Advanced Functional Materials (DOI: 10.1002/adfm.77922).
RMIT said it is seeking collaboration with imaging companies, industry partners and clinical researchers to explore potential applications.